velaco@vela.co.th

    6367 Precision LCR Meter

    Free

    6367 Precision LCR Meter

    The 6367 precision LCR meter is provided with high accuracy and speed. The test frequency from 10Hz to 1MHz. The 6367A test frequency from0.1Hz-1MHz, lowest test frequency from 0.1Hz. The difference between the new generation of LCR meters and the older generation LCR meters is that the measurement speed is faster and the accuracy is all up. It can show four measurement parameters Simultaneously. LCR meter is able to perform the component test entirely.

    In addition to measuring all kinds of components, but also can be used in the car battery, cell phone battery itself charge and discharge capacitors, UPS power system and other large energy power supply stable capacitor.

    Share on:

    Description

    • Basic accuracy up to ±0.08%
    • The lowest test frequency from 0.1Hz (636XA series)
    • Synchronous tests with four parameter settings
    • User-friendly interface, easy to operate
    • Support fully test functions
    • Interface: GPIB, RS232, Handler and USB
    • 7 inch 800*480, TFT LCD color screen
    • Multi step function

    Measurement Data

    Model Name6367
    Test Frequency10Hz-1MHz
    Model Name6367A
    Test Frequency0.1Hz-1MHz
    Points Of Test Frequency Continuity
    Basic Accuracy ± 0.08%
    AC Drive Level 10mV to 2Vrms (1m Vrms solution)
    DC Drive Level 0.01V-2V
    Output Impedance 100Ω
    Frequency trimming resolution 5 Digits
    Frequency output accuracy ±0.01%
    AC / DC test speed Max. 8mS

     

    Specifications

    Measured Value Detection ModeDefine upper and lower thresholds according to main and sub parameters
    ESRSeries/Parallel
    Test ModeMeter mode/Multi-step mode
    Test RangeAutomatic/Lock
    IndicatorPass/Fail and Built-in speaker
    SafetyEN61010-1
    ImmunityEN61326-1
    EmissionsEN55022 Class A
    CalibrationOpen Circuit / Short Circuit: Avoid the misreading caused by the stray capacitance from kelvin clips and fixtures
    Auto-save when power-off functionWhen the power is turned off or encounter a power outage, all the data will be saved automatically and recovered when tester system is switched on again
    Power SupplyVoltage 90-132Vac or 198-264Vac (selectable)
    Frequency 47 ~ 63Hz
    Display800*480 Color Screen, 7″ TFT
    InterfaceRS-232, GPIB, Handler, USB
    Flash MemoryBuilt-in flash for storage of 128 groups of Multi-steps setting
    OperationAuto、Manual、RS-232、GPIB、Handler
    EnvironmentTemperature : 10°C to 40°C Humidity : 20 ~ 90%
    Dimension (W*H*D)344x145x343 mm
    Weight3 Kg

     

    Parameters Measurement Ranges

    |Z| R X0.001mΩ – 99.999MΩ
    |Y| G B0.1nS – 99.999S
    Cs Cp0.01pF – 9.9999F
    Ls Lp0.1nH – 99.999KH
    D0.00001 – 9.9999
    Q0.1 – 9999.9
    DCR0.001mΩ – 99.999MΩ
    Δ%-9999% – 9999%
    Θ±0.001 ~ ±180.000deg

     

    Applications